Temperature NP200

NP200
– Multi input/output, high accuracy (+/-0.1%)
– 30 patterns, 300 segments (1 pattern / 99 segments)
– Heat & cooling PID control
– 3 level PID selection (4 PID groups)
– PID auto-tuning mode 2 types
– Digital input(DI) 7 contacts, User output(UO) 10 contacts
– Communication fuction (RS485/422)

 Suffix code

Model Number Function
NP200  Programmable Temperature Controller
Control Type 0  Normal type (heating)
1  Heating/Cooling type (synchronous control type)
Option 0  None
1  Communication function (RS485/422)
2  Contact input 4 contacts
3   Communication Function (RS422 / 485) + Contact input 4 contacts

Temperature controller Programmable NP200

· Specification

Model NP200
Appearance
W × H × D (mm) 96 × 96 × 100
Power voltage 100 – 240 V a.c (50/60 ㎐), voltage fluctuation rate ± 10 %
Power consumption Max. 6.0 W / Max. 10 VA
Input
T.C : K,J,E,T,R,B,S,L,N,U,W,PLII
R.T.D : Pt100(KS/IEC), KPt100(KS)
DC Voltage input : 1 – 5 V, -10 – 20 mV, 0 – 100 mV,
DC Current input : 4 – 20 mA(attach 250 Ω external resistor)
Control output Relay output, voltage output (SSR), current output (SCR)
Control operation PID control,  ON/OFF control
Alarm type High/Low, High/Low deviation
Communication method RS 485/422, 2-wire half-duplex or 4-wire hlaf-duplex
Setting By front Shift up, Down keys
Display PV : Digital LED , SV : Graphic LCD
 Accuracy 0.1 % of Full Scale
Setting accuracy 1 or 0.1% (According to input range)
External control 4 alarm output (Run, Reset, Step, Hold)
Number of pattern contact 30 patterns, Up to 99 segments per pattern can be set
Segment 300 segment
Set time unit of program Hours, Minutes, seconds
Sampling cycle 100 ms
Insulation resistance Min. 500 V a.c 20 ㏁
Dielectric strength 2300 V a.c 50/60 ㎐ for 1 min
(between 1st and 2nd terminals and between 1st terminal and ground)
Ambient temperature & humidity 0 ~ 50 ℃, 35 ~ 85 % R.H. (without condensation)
Weight Approx. 696 g